AccuTOF™ GC series Petroleum and Petrochemicals Applications Notebook
- Summary
Edition August 2021
This is a compendium of petroleum and petrochemicals related applications notes and JEOL News articles based on the data acquired on JEOL high resolution GC-TOFMS AccuTOF™ GC series (JMS-T100GC, JMS-T100GCV, JMS-T200GC, and JMS-T2000GC).
- Please see the PDF file for the additional information.
Another window opens when you click.
PDF 9.47MB
Table of Contents
Introduction P1~
- MultiAnalyzer – Unknown Compounds Analysis System New Gas Chromatograph – Time-of-Flight Mass Spectrometer JMS-T2000GC "AccuTOF™ GC-Alpha"
(Ubukata, M., JEOL news, 56, 66 – 72, 2021) - Effect of JMS-T2000GC high mass resolution on the analysis result -KMD Plot comparison using msRepeatFinder- (MSTips No. 332)
- Effect of high mass accuracy on the analysis result by JMS-T2000GC -Effect to narrow down the result of msFineAnalysis integrated analysis- (MSTips No. 331)
- Development of an Integrated Analysis Method for the JMS-T200GC High Mass-Resolution GC-TOFMS by Electron Ionization and Soft Ionization Methods
(Ubukata, M., Ueda, Y., JEOL news, 50, 83 – 89, 2019) - Comparison of performance between PI and FI by using GC-HRTOFMS
- High-speed 50 Hz Data Acquisition Capability for Comprehensive 2-dimensional GC Measurements (MSTips No. 226)
- The Qualitative Analysis of an Antioxidant Additive Using the Full Capabilities of the EI/FI/FD Combination Ion Source (MSTips No. 224)
GC/MS, GCxGC/MS P35~
- Biomarker Analysis in Petroleum Samples Using GC×GC-HRTOFMS with an Ion Source Combining Electron Ionization (EI) and Photo Ionization (PI)
(Ubukata, M., Ueda, Y., JEOL news, 53, 54 – 58, 2018) - GCxGC TOFMS Analysis of Base Oils with CI, PI, FI (MSTips No. 285)
- Diesel Fuel Classification Analysis Using GC x GC/FI and Kendrick Mass Defect Plots
- GC x GC/EI and GC x GC/FI Measurements Using the EI/FI Combination Ion Source (MSTips No. 225)
- Analysis of diesel oil by using GC x GC-HRTOFMS (FI) with 2 different sets of column combinations (MSTips No. 154)
- Accurate mass measurement of lube oil by GC/FI-TOFMS (MSTips No. 058)
- Qualitative analysis by comprehensive 2D GC / TOFMS [1]
- Comparison of kerosene and diesel oil – (MSTips No. 055) - Qualitative analysis by comprehensive 2D GC / TOFMS [2]
- Analysis of polycyclic aromatic hydrocarbons in kerosene – (MSTips No. 056) - Qualitative analysis by comprehensive 2D GC / TOFMS [3]
- Analysis of sulfur-contained substances in diesel oil – (MSTips No. 057)
Group-Type Analysis P61~
- Rapid analysis using inactivated fused silica tube (a.k.a. "guard column") as a sample inlet (1)(MSTips No. 111)
- Rapid analysis using inactivated fused silica tube (a.k.a. "guard column") as a sample inlet (2) (MSTips No. 112)
- Type Analysis of Micro Crystalline Wax (Petroleum Wax) (MSTips No. 100)
- Degradation of rotary vacuum pump oil determined by field desorption (FD) - TOFMS and group-type analysis software (MSTips No. 098)
- Group-type analysis of Crude Oil using GC/FI-TOFMS 1
~Determination of average molecular weights by group-type analysis~ (MSTips No. 071) - Group-type analysis of Crude Oil using GC/FI-TOFMS 2
~Reproducibility of group-type analysis results~ (MSTips No. 072)