JMS-S3000 SpiralTOF™ series Imaging Applications Notebook

  • Summary

Edition July 2020

JMS-S3000 SpiralTOF(TM) series Imaging Applications Notebook

This is a compendium of mass spectrometry imaging applications notes and JEOL News articles based on the data acquired on JEOL ultra-high mass-resolution MALDI-TOFMS JMS-S3000 SpiralTOF™ series.

Please see the PDF file for the additional information.
Another window opens when you click.

PDF 20.6MB

Table of Contents

Introduction and Fundamentals P1~

  • Development of JMS-S3000: MALDI-TOF/TOF Utilizing a Spiral Ion Trajectory
    (Takaya Satoh, JEOL News, 45, 34-37, 2010)
  • Mass Spectrometry Imaging using the JMS-S3000 "SpiralTOF™-plus" Matrix Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometer
    (Takaya Satoh, JEOL News, 55, 70-72, 2020)
  • High Mass Resolution MALDI-Imaging MS – High Stability of Peak Position during Imaging MS Measurement (MS Tips No.193) 
  • The Relationship between Crystal Condition and Mass Resolving Power, Mass Accuracy (MS Tips No.206) 

Life Science / Biomolecules P17~

  • High Mass-Resolution MALDI-imaging MS for Drug Metabolism in Tissue Using the JMS-S3000 (MSTips No.212)
  • High Mass Resolution MALDI-imaging MS Using JMS-S3000 SpiralTOF™ and msMicroImager  (MSTips No.211) 
  • Fingerprint Analyses Using MALDI Imaging and SEM Imaging (MSTips No.208)
  • MALDI-Imaging MS of Lipids on Mouse Brain Tissue Sections Using Negative Ion Mode (MS Tips No.196)

Polymers / Materials P33~

  • Degradation analysis of polyethylene terephthalate film by UV irradiation using imaging mass spectrometry and scanning electron microscopy (HS05)
  • Mass spectrometry imaging for degradation of polyethylene terephthalate by UV irradiation using JMS-S3000 "SpiralTOF™-plus" (MSTips No.307)
  • A mass spectrometry imaging method for visualizing synthetic polymers combined with Kendrick mass defect analysis (MSTips No.306)
  • A mass spectrometry imaging method for visualizing synthetic polymers by using average molecular weight and polydispersity as indices. (MSTips No.305)
  • Mass spectrometry imaging on mixed conductive/non-conductive substrate using JMS-S3000 SpiralTOF™ (MSTips No.288)
  • Analysis of organic compounds on an acrylic plate using JMS-S3000 "SpiralTOF™" (MSTips No.251)
  • Ballpoint Ink Analyses Using LDI Imaging and SEM/EDS Techniques (MSTips No.204) 
  • Gunshot Residues (GSR) Analysis by Using MALDI Imaging
  • Analysis of Organic Thin Films by the Laser Desorption/Ionization Method Using the JMS-S3000 "SpiralTOF™"
    (Satoh, T., JEOL News, 49, 81-88, 2014)