JMS-S3000 SpiralTOF™-plus Mass Spectrometry Imaging System

MALDI MS imaging was initially developed to focus on high molecular weight compounds such as proteins and peptides. However, with the expanding applications of MALDI MS imaging, the interests have shifted to include smaller molecules such as lipids, pharmaceuticals, and pharmaceutical metabolites. Conventional MALDI-reflectron TOFMS has difficulty discerning small molecule signals from those of matrix. In the case of MALDI MS imaging, signals from unwanted molecules on the specimen surface will often interfere with signals from the target analytes. High selectivity by means of high mass-resolving power is essential for obtaining reliable target analyte spatial distributions.
The SpiralTOF™-plus with its high mass-resolving power is indispensable for MALDI MS imaging.

A tissue section is placed on an ITO-coated glass slide, and matrix solution is sprayed onto the surface.
A special target plate for thick specimens is available as an option. The specimen is moved beneath the focused laser beam to create a time dependent series of mass spectra where each time corresponds to a specific spatial location. Analysis of the data allows the researcher to visualize the spatial distribution of specific compounds on the sample surface. Mass spectrometry imaging data can be analyzed with the JEOL msMicroImager software or converted to a common data format imzML which allows data analysis by third party software such as BioMap.

Mouse brain sections contain a variety of lipid classes. A mass spectrum obtained from the tissue section is highly complex, especially in the region of m/z 700 - 1,000. Many of the peaks in the mass spectrum are less than 10% of the base peak, representing minor components. MALDI MS imaging of lipids requires a mass-resolving power high enough to separate the minor peaks from interferences. The bottom mass spectrum below shows the expansion of m/z 820 - 823. Many peaks were separated from each other by less than 0.1 u. The high mass resolving power of the SpiralTOF™-plus clearly separated these isobaric peaks, thus allowing the elucidation of 4 lipid elemental compositions. Moreover, each lipid clearly showed a different spatial distribution. Elucidation of elemental compositions and accurate determination of spatial distributions for each lipid would be difficult with a conventional reflectron TOFMS with moderate mass-resolving power.


The data were acquired in a joint research project with the Mass Spectrometry Group, Project Research Center for Fundamental Sciences, Graduate School of Science, Osaka University.
The tissue section specimen was provided by Awazu laboratory, Division of Sustainable Energy and Environmental Engineering, Graduate School of Engineering, Osaka University.

Catalogue Download

Specifications

Options

Model name Description

Target plates

Sample plate holder

For ITO glass sample plate (Hudson Surface Technology)
ITO glass sample plate, 0.7 mm thick,
25/package (Hudson Surface Technology; HST)
Multi-target plate For thick specimens
Indentations for 0.5 mm thick and 1.0 mm thick specimens.
Software MS-56530MSI
MS Imaging Support Program
1D (line) scan and 2D scan (imaging) data acquisition.
Convert MS imaging raw data into imzML format.
msMicroImager™
MS-56550MSIV
MS Imaging Viewer Program
Read MS imaging raw data acquired by msTornado™ Control. Perform pixel binning.
Extract and export MS images. Export mass spectra of the regions of interest.
Browse MS images. Change color map of the images.
Perform arithmetic operations between MS images. Overlay MS images.
BioMap BioMap is developed and copyrighted by Novartis Institute for BioMedical Research (Basel, Switzerland) and available from the MALDI Mass Spectrometry Imaging Interest Group (MALDI MSI IG) web site.

Top: multi-target plate for thick specimens (for 0.5 mm thick and 1.0 mm thick specimens)
Bottom: sample plate holder for ITO (indium tin oxide) coated glass slide by Hudson Surface Technology